'Aneurysm Number' may help surgeons make treatment decisions

'Aneurysm Number' may help surgeons make treatment decisions
These schematics show the vortex ring versus the stationary shear layer in the sidewall anatomic aneurysm. Credit: Hafez Asgharzadeh, Hossein Asadi, Hui Meng and Iman Borazjani

Aneurysms form as abnormal bulges or balloonings over an artery, and, if ruptured, can lead to serious health complications or even death. Some aneurysms can exist for a long time without rupturing, and the surgery involved in treating aneurysms can be quite risky, so a parameter to help guide surgeons is needed.

Today, treatment decisions are made mainly by assessing the geometric parameters such as the size of an aneurysm, which is obtained from medical images. But the are known to be an important factor in the initiation, growth and rupture of aneurysms. The factors determined by flow, such as the and its oscillations on the walls of an artery, require cumbersome flow measurements and . A simple parameter that depends on both flow and geometry, which can substitute flow factors (that require flow measurements and simulations) doesn't exist.

But now, as researchers from the University at Buffalo and Texas A&M University report in the journal Physics of Fluids, they have developed a simple nondimensional parameter that depends on both geometry and flow waveform to classify the flow mode in both sidewall and bifurcation aneurysms.

"This simple parameter, called 'aneurysm number (An),' is the ratio of time scales of two competing phenomena in aneurysms: First is the transport time scale, which represents the transport of a fluid particle through the aneurysm expansion," said Iman Borazjani, an associate professor at Texas A&M. "Second is the formation time scale, which represents the formation of a vortex due to the pulsatile flow into an expansion."

The transport phenomenon creates a stationary shear layer through the expansion region, he explained, whereas the vortex phenomenon likes to create a vortex ring. If the transport time scale is smaller (An<1), then a stationary shear layer is formed and the flow mode is called the cavity mode. Otherwise, a ring vortex is formed (An>1) and the flow mode is the vortex mode.

The group's work is a significant breakthrough because they were able to show that not only can their aneurysm number classify the flow mode in both simplified and anatomic geometries, but also that the oscillations of shear stress are higher in the flow in the vortex mode (An>1). "This means that our simple parameter might be a good substitute for the oscillatory shear parameter—without the need for challenging flow measurements and simulations to calculate shear on the wall," Borazjani said.

When the researchers first submitted their simplified work, several reviewers questioned whether the results for simplified geometries are applicable to real anatomic ones. "They weren't convinced, so we had to show that our parameter works for anatomic geometries. Now, a pair of articles are being published together," Borazjani said, explaining why the group went on to write a second article about their work. They first developed and tested their parameter for simplified (idealized) geometries in part I of their article, and then applied it to anatomic ones in part II.

Oscillatory shear, which is related to the group's parameter, is thought to affect the endothelial cells and promote inflammation, growth of aneurysms, and even their rupture. For example, "a vortex mode is more likely to rupture because it has a higher oscillatory shear," Borazjani said. "Therefore, we think our simple parameter can help surgeons in making decisions to treat an in the future."

More information: "A non-dimensional parameter for classification of the flow in intracranial aneurysms I: Simplified geometries," aip.scitation.org/doi/full/10.1063/1.5081451

"A non-dimensional parameter for classification of the flow in intracranial aneurysms II: Patient-specific geometries," aip.scitation.org/doi/full/10.1063/1.5033942

Journal information: Physics of Fluids

Citation: 'Aneurysm Number' may help surgeons make treatment decisions (2019, March 26) retrieved 29 March 2024 from https://phys.org/news/2019-03-aneurysm-surgeons-treatment-decisions.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

Drag reduction and relaminarization of wall-turbulence by traveling wave control

77 shares