Detecting hydrogen using the Extraordinary Hall Effect in cobalt-palladium thin films

Researchers looking to hydrogen as a next-generation clean energy source are developing hydrogen-sensing technologies capable of detecting leaks in hydrogen-powered vehicles and fueling stations before the gas turns into an explosion. The most common type of hydrogen sensors is composed of palladium-based thin films because palladium (Pd), a silvery-white metal resembling platinum, readily absorbs hydrogen gas. However, Pd also readily absorbs other gases, decreasing the overall efficiency of these sensors.

Alexander Gerber's research team at Tel Aviv University recently conducted a systematic study of detection using the Extraordinary Hall Effect (EHE) to measure the hydrogen magnetization response in cobalt-palladium (CoPd) thin films. The team reports the findings in the Journal of Applied Physics.

"We found that detection of hydrogen by EHE really works with very high sensitivity," said Alexander Gerber, an author on the paper. "A goal would be to develop a compact EHE device compatible with a standard four-probe resistance measuring method to enhance gas detection through a magnetic type of sensor using the spintronics effect."

The burgeoning field of spintronics exploits an electron's spin and its resulting magnetic properties. In essence, EHE is a spin-dependent phenomenon that generates voltage proportional to magnetization across a current-carrying magnetic film.

Otherwise known as the anomalous Hall effect, EHE occurs in ferromagnetic materials and can be much larger than the ordinary Hall effect. Although palladium has high hydrogen absorption capacity, it's not ferromagnetic by itself. So, the researchers added cobalt, a ferromagnetic material whose are affected by the hydrogen absorption in CoPd alloys to induce EHE.

The researchers prepared four sets of samples with thicknesses of 7, 14, 70 and 100 nanometers with varying cobalt concentrations and tested them in an atmosphere with different levels of hydrogen up to 4 percent. They found that the thinnest films demonstrated the largest absolute response to hydrogen: The signal changes by more than 500 percent per 1 percent of hydrogen.

"In practical terms, we identified the sensitive range of compositions, how the response to hydrogen depends on composition, and what the options are to operate the sensor," Gerber said.

Gerber's research team is now in the process of recording response times and exploring the ability to release hydrogen after exposure so can be reused. The researchers also plan to explore ways to improve selectivity of hydrogen and adapt their technique for selective detection of other gases.

More information: S. S. Das et al, Detection of hydrogen by the extraordinary Hall effect in CoPd alloys, Journal of Applied Physics (2018). DOI: 10.1063/1.5049647

Journal information: Journal of Applied Physics

Citation: Detecting hydrogen using the Extraordinary Hall Effect in cobalt-palladium thin films (2018, September 12) retrieved 16 April 2024 from https://phys.org/news/2018-09-hydrogen-extraordinary-hall-effect-cobalt-palladium.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

A hydrogen sensor that works at room temperature

39 shares

Feedback to editors